6
7
FIND THE FEED CABLE
1
2
3
4
Diagram 1
1
2
3
4
Diagram 2
Safety
1
2
3
Cable 4
Auxiliary Cable
Diagram 3
The efergy monitor is installed by cliping the sensor around the feed cable of your
electricty meter.
LOCATE YOUR ELECTRICITY METER
Locate your electricity meter and determine its type. You
can normally find this on an outside wall, in the garage,
basement or utility room. If you live in a flat, it can often be
found outside your front door, in the communal stair case, or
in the basement. Ensure there is enough of accessible cable
coming from the bottom of your electricity meter.
Modern office blocks and apartments may have safety panels
to protect wires entering the meter. It is recommended that
professional electricians be contacted where this is the case.
FIND THE FEED CABLE
You should find four cables exiting the meter. The feed cable
(Cable 4) is the live cable exiting from the meter to the fuse
box. Connect the sensor to Cable 4 (Cable 4 will generally be
on
the right hand end of the meter, see Diagram 1).
Some installations will have Cable 1 and Cable 2 covered,
or partially covered to prevent any tampering with the supply
(see Diagram 2). Attach the sensor to Cable 4 (far right cable).
Feed Wire
Feed Wire
Dual Tariff meters (Diagram 3) will
often have an Auxiliary cable running
between Cable 3 and Cable 4. Auxiliary
cables will be smaller in diameter
than the feed cables, and will run
into an adjoining metering device.
Newer installations will normally have
two cables exiting from the bottom
of the meter. One is the earth cable,
the other the live feed cable. The
sensor should be clipped around the
live feed cable (this is normally brown
coloured).
If you have a three phase supply, or
economy 7 meter, then you may require
additional sensors. These can be simply
plugged into the additional sockets at
the base of the transmitter. Please
contact your supplier for additional
sensors.
UNDER NO CIRCUMSTANCES SHOULD
YOU TRY TO ATTACH THE SENSOR IF
THERE IS ANY DAMAGE TO THE ELECTRIC
METER CABLES. NO CABLES NEED TO
BE CUT. DO NOT CUT ANY CABLES.
Feed Wire
CONTACT YOUR LOCAL ELECTRICITY
SUPPLIER IF YOU HAVE ANY CONCERNS
ABOUT CLIPPING THE SENSOR ONTO THE
CORRECT CABLE.